The temperature background and the high level of moisture in the bath are favorable conditions for the resettlement of all kinds of harmful microorganisms. Among them are bacteria, viruses, molds that destroy wood and the pulmonary system of bathhouse lovers. Properly made ventilation in the bath will save from the above negativity. How to make it?
We will tell you all about the rules for organizing ventilation systems designed to dry wet rooms. The use of reliable information will help to develop and implement a perfect ventilation project. The data presented for consideration are based on building codes and practical experience of builders.
The article describes in detail the methods of constructing ventilation systems intended for removing suspended water in the air, drying the finish and supporting structures. The materials and components required for their arrangement are described. Effective help in mastering a difficult topic will be provided by photo applications and video guides.
The specifics of ventilation systems for the bath
The bathhouse needs regular air renewal. This is a safety requirement for people taking bath procedures. Also, proper ventilation can extend the life of up to 50 years or more.
The type of ventilation system is selected individually and depends on the location, size of the structure, and materials used in the construction.
Bath ventilation schemes
All existing ventilation systems according to the principle of action are divided into natural, forced and combined. In the first case, airing occurs due to the arbitrary intake of street air, its mixing in the room and the displacement of exhaust through holes in a natural way.
Image Gallery
Photo from
The organization of the ventilation system in the bathhouse is required not only by visitors, but also by the structure itself, especially if it is made up of timber or logs
Sauna stoves, especially wood-burning units, need a supply of oxygen to support the combustion process
To extend the life of the structure and bath items, regular drying is necessary, in which ventilation and ventilation are involved
Normal conditions for people, furnishings, structures and equipment in a bathhouse through a window and doorways are not enough. They will only help to dry better and faster.
By the method of inducing the air mass to move the ventilation systems are divided into natural, mechanical and combined. In baths with natural ventilation, indoor air changes are based on the laws of gravity
To ventilate large bath complexes, including several functional rooms and rest rooms, a mechanical system is needed. It moves air through the operation of the fan.
At the place of installation of the fan, mechanical systems are divided into supply and exhaust. Air-blowing fans are installed on the inlet, air-venting fans are installed on the exhaust hood
In the combined variants: if the fan pumps air, it is diverted through the exhaust outlet naturally, if the fan is bleeding air, then its volume is renewed by natural influx
Well-dried bath room
Supply of oxygen for furnace operation
Dried accessories and finishes
Supply valve near the window
Natural ventilation exhaust
The mechanical version of the system
Exhaust fan on a wooden wall
Combined system inlet
Secondly, an additional device, a fan, is included in the work. Most often, they put it on the hood, but it is possible on the inflow. A fan is used in each of the rooms of the bath. In the third - a symbiosis of the first and second options.
When choosing a fan for hoods, you must always pay attention to its degree of protection (IP44 above) and the case, which should be heat resistant
Among the ventilation schemes used in baths, the most popular bastu. It implies an inflow port with an adjustable valve, which is located behind / under the furnace. Additionally, under the furnace there may be vents controlled by a valve or a valve. Through them air enters from the underground, penetrating from the street through the ventilation in the foundation.
Among the fans for the bath you can find almost silent models. They are powerful, creating noise when working at 22-35 dB
The top hole of this box is closed until the right time. As soon as there is a need to dry the room, immediately open 2 exhaust valves.
Such a seemingly ideal scheme is not always suitable. Then apply a forced ventilation option. If you add an exhaust fan to the lower part at the entrance to the ventilation duct in this circuit, you get an exhaust system. When installing the fan in the supply opening behind / above the furnace, we get the supply ventilation circuit of the steam room.
Cold air, getting into the steam room, immediately warms up. And the exhaust is forced out into the lower hole of the ventilation duct, located on the opposite wall
Another ventilation scheme used in baths, when the inflow occurs through vents located in the lower part of the room, next to the floor, and removal through a hole arranged at the top with ventilation valves installed in them.
Outside, these holes are connected by a common ventilation duct, rising to a certain height. The height of the lower exhaust valve is about 50-60 cm from the floor, and the upper one is 30-40 from the ceiling.
It is convenient to use the bastu circuit, equipping the holes with special adjustable valves. After all, you can open and close them as necessary, setting the appropriate gap / hole size
The ventilation scheme, in which one channel is used for the inflow and one for the removal of air masses, is also used in bathhouses. Moreover, these 2 holes are located at the same height from the floor. The first is behind the stove, and the second is on the opposite wall. It is imperative to install an exhaust fan here in order for the ventilation system to work.
All components used for the ventilation device, you need to select the appropriate level of moisture and heat resistance, specially designed for baths and saunas
The most unfortunate option is when the supply and exhaust are arranged on the same wall, just opposite the stove. Unfortunately, such a picture is also not uncommon when other schemes can in no way be applied in specific conditions.
With this scheme, fresh air, entering the room, is looking for a path to the furnace, simultaneously bumping into the feet of soaring. Then, being in the right place and warming up, it rises up, mixes with steam and flies out into the hole located 20-30 cm from the ceiling. He does not have time to fully work out, saturated to the extent necessary with carbon dioxide.
The poor location of the ventilation openings in the bath is fraught with drafts and insufficient oxygen saturation of the room
Structural components of the system
In the bathhouse, ventilation is necessary for the safety of people and ensuring acceptable operating conditions for the materials of the room itself. The development and installation of a ventilation system does not mean at all that a huge amount of money has to be spent on the implementation of useless projects.
High-quality ventilation of the bath is not at all equivalent to expensive ventilation. Everything will depend on the specific conditions of a single building.
High-quality ventilation, implemented in the bath, includes ventilation and drying:
- all premises;
- wall constructs;
- drying floors;
- ventilation of the attic and roof space.
As the ventilation holes in the attic, special windows, spotlights or aerators are installed - it all depends on the type of roof and materials. Drying of the roofing pie is ensured by ventilation of the subroofing space.
If there is insulation, then a counter-grill is required to ensure ventilation between the insulation and other layers of the roof. It is also used for ventilating wall structures so that condensation does not form in the thickness of the layers.
To dry the floors, use volley airing or equip a ventilated floor. This option should be provided at the construction stage. To do this, carry out a rough floor, carefully pour concrete at a slope, and finish the floor from hardwood boards, leaving small gaps between them. This floor provides a quick removal of excess moisture.
It is important to properly organize ventilation in all rooms of the bath. Particular attention should be paid to the washing / shower, where increased humidity threatens the formation of fungus and mold
All rooms of the bathhouse need ventilation, including:
- steam room;
- washing;
- dressing room / lounge;
- other premises.
In order to arrange proper ventilation, it is necessary to choose the optimal scheme that suits the requirements and conditions of a particular bath. It is important to remember that fresh air must enter all rooms and also be removed from all.
They build ventilation ducts, make supply and exhaust openings in the walls, or mount a whole duct system - all very individually
Experienced masters do not recommend laying complex systems of ventilation ducts, preferring to dwell on the simplest solution, suitable for a particular case. The rule works here - the simpler the better. Yes, and for the price of a simple option will cost several times cheaper.
Image Gallery
Photo from
Classic air inlet
Exhaust vent location
Hood on the ceiling of the bath
Duct in the overlap of the frame bath
Owners of Finnish saunas and bath complexes with two or more types of steam rooms, including the oriental hammam, are advised to familiarize themselves with the specifics of the ventilation device in the sauna, described in detail in the proposed article.
The dependence of ventilation on the material of the walls of the bath
The ventilation system for the bath directly depends on the type of room itself and the material from which it was built. It can be a separate building or several rooms in a long-built house. The first option is preferable - it is convenient to plan and arrange a ventilation system here, choosing the most inexpensive way.
If the bath is adjacent to residential premises, special attention should be paid to its drying, in order to protect the walls of the house from rotting. Also, do not forget that the temperature in the steam room will be high, so the adjacent walls need to be additionally made heat-resistant.
Most often, in a part of a residential building, they do not arrange a familiar Russian bath, but a sauna, in which there is less steam and more heat
In this case, the ventilation system will only be forced. It must take into account the safety of walls and supporting structures of a residential building. The ventilation system of such a bath will be part of the entire house system. Ventilation ducts can be connected to common houses or go to the roof separately or through the wall to the street.
Depending on the type of material baths are:
- from a brick;
- logs;
- from gas blocks;
- timber;
- wooden frame with insulation.
In brick and frame baths, ventilation ducts can be arranged in the walls, leading them to the roof or higher. An air duct is laid for the inflow, a ventilation valve or vents in the foundation are used. It is imperative to supply an exhaust fan to better remove exhaust air.
If the bath is located in the basement, then install a basement deflector to ensure optimal traction
Due to the specifics of the material of the walls, gas-block baths are equipped with galvanized air ducts, buying finished pipes. Sometimes a ventilation duct is made of galvanized sheets, giving them the appropriate shape and securely sealing all joints. Ducts must pass over the wall.
If logs are used as the material, then natural supply ventilation is possible due to the characteristics of wood and construction technology. When the tree breathes, there are necessary gaps between the logs, windows are provided in all rooms of the bathhouse, gaps are arranged from the floor to the lower edge of the door of 2-3 cm, the construction of additional ventilation channels may not be necessary.
Vivid examples of baths built 50 and more years ago are still alive. They have become even stronger from time to time, and soaring in them is a pleasure
But it is very difficult to achieve the optimal ratio between the incoming air and the leaving steam. In order to avoid drafts and not to drown the entire street, it is often preferred to additionally insulate a wooden bathhouse by arranging inside holes with valves to remove / enter air.
Features of the ventilation system
A large role in choosing the optimal ventilation scheme is played by the material of the bath, its location, whether it is freestanding or not. All this helps to make the right decision when installing the sensor system.
One of the effective methods of ventilation is volley airing - when you need to quickly ventilate everything, all doors and windows open. Of course, this can be realized if there are windows.
With volley airing in a matter of minutes, the main moisture goes away, preventing the wooden finish of the premises from getting wet
In the ventilation of the bath take part:
- window;
- vents in the foundation;
- special holes in the wall / ceiling;
- doors and the gap under them.
The solution with installing a window in the steam room is very good, another thing is that it is not always possible to implement it. It is in such cases that it is necessary to choose another option for organizing the ventilation of the room.
Image Gallery
Photo from
Supply air vent
Exhaust hole with access to the attic
Sunroof in the ceiling for ventilation
Fabric valve for exhaust vents
Ventilation in the foundation is also not often possible to use. Especially if the owner decided to separate one of the rooms of the house under the steam room, the foundation of which is not equipped with special openings. Here forced ventilation with a carefully selected layout of supply and exhaust openings will come to the rescue.
No matter how you want to protect the room from steam leakage, carefully covering it with vapor-tight materials and fitting the doors tightly, you should not do this. Under the door to the steam room, you should definitely leave a gap of 2-3 cm and nothing else.
The gap under the steam room door will provide a more even flow of air, which will favorably affect soaring people
For the flow of air, it is advisable to make holes in the lower part of the room that communicate with the street. After all, the room needs clean and fresh air, especially if the bathhouse is located outside the city limits next to coniferous or deciduous forest.
Holes designed to remove exhaust air are located in the upper part of the walls opposite to the walls with inlet valves. Moreover, their height depends on the selected ventilation scheme and starts from 80 cm from the floor level or more. It is also possible to install an exhaust valve in the ceiling with a vent duct on the roof.
The inlet openings are closed with valves, valves, so that it is convenient to control them in the process of receiving bath procedures
Ventilation components
To create favorable conditions in the steam room of the bathhouse and in all additional rooms, it is necessary to properly arrange the ventilation system.Otherwise, there can be no talk of any comfort.
The components used for the ventilation device are as follows:
- vent valve;
- gate valve;
- lattice;
- mosquito net / protective net;
- ventilation duct;
- galvanized or corrugated duct;
- fan;
- hygrometer, thermometer;
- metal tape, clamp, mounting foam, sealant, fasteners and other consumables for installation and design of inlet and outlet openings.
Ventilation valves for ventilation in the bath are placed on the supply and exhaust openings. They come in various sizes, shapes and materials. Therefore, it is not difficult to choose a valve that is perfect in color.
Valves for ventilation, which are unscrewed / twisted, are most convenient to use, allow you to leave very small gaps for the intake of micro portions of air
Gate valves are also available in various designs. They are needed to open / close openings if necessary. Often, home craftsmen make a home-made design that copes with the function of removing / inflowing air masses from rooms no worse.
Image Gallery
Photo from
Installation of an angular diffuser
Infinitely variable airflow
Anemostat for ventilation and air conditioning systems
Connection of an anemostat to an air duct with a coupling
The grille and mesh are needed to protect the ventilation hole from getting into rodents, moths, mosquitoes and other animals. Lattices are selected from wood, heat-resistant plastic, and the mesh is most often made of metal.
It is not practical to place a grate of soft material on the supply air holes - rodents can ruin it. Better choose metal options
A ventilation duct is installed in a wall niche or, if conditions do not allow it, laid on top, for example, if aerated concrete is used as the wall material. The box can be made from improvised materials or used as a duct corrugation or galvanized pipe. Plastic analogues for the steam room will not work - you need to take into account the temperature to which the room will heat up.
The fan in the bath is used both for inflow and for exhaust. Its use is considered optimal only in one of the directions - for the inflow or removal of air masses.
You need to buy a heat-resistant device specially designed for baths and saunas with IP 44 and above. Do not forget about the specifics of the room - there is a lot of steam and high temperature.
If there is a pool in the bathhouse, then forced ventilation is indispensable. The pool is an additional room where water evaporates around the clock. A tree does not like it
Consumables are used during installation for mounting air ducts, arranging ventilation ducts and installing valves, fans. A hygrometer and a thermometer are needed to effectively use the ventilation system.
If mechanical ventilation with the use of climate technology is arranged, then there is a built-in temperature sensor and a humidity level regulator. Based on the real indicators of the devices, the system starts the exhaust fan or opens the supply valve.
The installation of ventilated floors is planned at the construction stage. They realize this type of ventilation together with the construction of the draft and then the final floor, choosing the most affordable option for themselves at a price
Properly equipped ventilation will ensure a comfortable stay in all rooms of the bathhouse, not clouded by third-party odors and drops of water flowing down the walls and falling from the ceiling behind the curtain.
Another important condition for a long service life is timely and complete drying after use. It depends on the implementation of this paragraph how long the bath will last and whether it will be necessary to replace rotten boards with new ones in the next 3-5 years.
When there is no ventilation, and the owner of the bath tightly closes the doors and windows after use, you can detect fungus, mold, rot in a year
Effective ventilation organization schemes in the steam room:
Variants of the ventilation device in the new bath:
The lack of ventilation channels in the bath can turn into costly troubles:
For the rational and long-term use of the bath, it is important to properly equip the ventilation system. It is necessary to choose the most suitable option, suitable for specific conditions, capable of providing an influx of fresh air and removing exhaust air in the required volume. If in an idle bath it’s dry, but in a warm bath it’s comfortable and doesn’t drip on your head, then we managed to cope with the ventilation task perfectly.
Do you have any questions while reviewing the information provided? Do you want to talk about the nuances of organizing ventilation in a bathhouse known only to you? Please write comments in the block below, post thematic photos, share your impressions.